1.5MM ANGULAR PLATE
A 1.5mm angular plate is a type of orthopedic implant used in fracture fixation, particularly in cases where stabilization along specific angles or contours is required. Let's delve into its specification and potential uses:
Specification
- Thickness: The plate is 1.5mm thick, providing a balance between strength and profile to minimize soft tissue irritation while offering adequate stability.
- Angular Plate Design: The angular plate is designed to conform to specific angles or contours of bone surfaces. It may have a pre-contoured shape to match the anatomy of the bone where it will be applied, facilitating easier surgical placement and better adaptation to the bone surface.
- Material: Like other orthopedic implants, angular plates are typically made from biocompatible materials such as titanium alloy or stainless steel, ensuring compatibility with the body and providing adequate strength for fracture fixation.
Uses
- Complex Fractures: Angular plates are primarily used in the stabilization of complex fractures with specific geometries or orientations. They allow for fixation along non-linear or irregular bone surfaces, maintaining alignment and promoting healing in challenging fracture patterns.
- Periarticular Fractures: Fractures near joints, such as intra-articular fractures, often require stable fixation to preserve joint function and prevent post-traumatic arthritis. Angular plates can be beneficial in these cases, offering versatile fixation options to accommodate the unique anatomy and loading patterns near joints.
- Osteotomies: Angular plates are also used in osteotomies, where bones are intentionally cut and reshaped to correct deformities or improve function. The pre-contoured shape of the plate allows for stable fixation along specific angles or contours, facilitating precise bone realignment during healing.
- Revision Surgeries: In cases of nonunion, malunion, or failed prior fixation, where additional stability or a different fixation construct is needed, angular plates may be used in revision surgeries to achieve proper alignment and stability, promoting successful healing.
- Minimally Invasive Surgery (MIS): The low-profile design of 1.5mm angular plates makes them suitable for use in minimally invasive surgical techniques, where smaller incisions are made to access the fracture site. This can help reduce surgical trauma and promote faster recovery for the patient.
As with any orthopedic implant, the specific use of a 1.5mm angular plate will depend on factors such as the nature and location of the fracture, the patient's overall health, and the surgeon's expertise and preference. Consulting with an experienced orthopedic surgeon is essential to determine the most appropriate treatment plan for individual cases.